Replacing Application Cards
▀ Determining Whether an Application Card has Failed
▄ ASR 5000 Installation Guide
240
Determining Whether an Application Card has Failed
The system has several ways to indicate an application card failure. The first indicator is that the Status LED on the
System Management Card (SMC) turns red to indicate the failure of a chassis component. Another indicator is the
Run/Fail LED on an application card is red or turns off if that card has a problem.
If you see either of these indicators, you can determine the nature of the problem via the CLI or by checking the Simple
Network Management Protocol (SNMP) traps.
Using the CLI
Monitor application cards in the chassis by executing the following CLI commands in Exec mode:
show card diag
slot_#
slot_# is the chassis slot number in which the particular card that you wish to monitor is installed. For application cards,
slot_# is any integer between 1 and 16. The following is a sample output for this command to monitor the card in
chassis slot 8:
Card 8:
Card Usable : Yes
Card Tests : Pass
Boot Mode : Normal
show card info
slot_#
The following is a sample output for this command issued to monitor the card in chassis slot 8:
Card 8:
Slot Type : SMC
Card Type : System Management Card
Operational State : Active
Last State Change : Thursday January 27 16:00:32 EST 2008
Administrative State : Enabled
Card Lock : Locked
Reboot Pending : No
Upgrade In Progress : No
Card Usable : Yes
Single Point of Failure : No
Attachment : 24 (System Processor I/O Card)
Attachment : 25 (System Processor I/O Card)
Temperature : 24 C (limit 101 C)
Voltages: : Good
Card LEDs : Run/Fail: Green | Active: Green | Standby: Off
System LEDs : Status: Green | Service: Off
CPU 0 : Kernel Running, Tasks Running
If any of this information appears to be erroneous, such as the operational state or an LED state, check for any of the
SNMP alarms listed in
Summary of Contents for ASR 5000 Series
Page 9: ...Contents ASR 5000 Installation Guide ix Spare Component Recommendations 317 ...
Page 10: ......
Page 14: ......
Page 54: ......
Page 64: ......
Page 90: ......
Page 104: ......
Page 122: ......
Page 126: ......
Page 186: ......
Page 194: ......
Page 206: ......
Page 228: ......
Page 276: ......
Page 284: ......
Page 290: ......
Page 300: ...RoHS Compliance Statement Chassis ASR 5000 Installation Guide 300 Chassis ...
Page 301: ...RoHS Compliance Statement Fan Assembly ASR 5000 Installation Guide 301 Fan Assembly ...
Page 303: ...RoHS Compliance Statement Full Product ASR 5000 Installation Guide 303 Full Product ...
Page 304: ...RoHS Compliance Statement Full Product ASR 5000 Installation Guide 304 ...