Cabling the Power Filter Units
▀ Connecting the PFU to the Power Source
▄ ASR 5000 Installation Guide
152
Step 6
Reinstall the plastic terminal cover.
Caution:
To avoid the risk of potential damage to the system, never operate the chassis without the plastic
terminal cover installed. Make sure that the power and return lugs do not protrude past the edge of the plastic terminal
covers. Any portion of the lug that is exposed must be covered with heat shrink tubing.
Step 7
Repeat step 1 through step 6 for the PFU installed in the bay labeled Power Filter Unit 2.
Step 8
Proceed to the next chapter for information and instructions on applying power to the chassis and verifying that the
installation was successful.