ASR 5000 Hardware Platform Overview
Application Cards ▀
ASR 5000 Installation Guide ▄
31
Item
Description
5
PC-Card/PCMCIA Slot
—Stores or moves software, diagnostics, and other information.
6
System Alarm Speaker
—Sounds an audible alarm when specific system failures occur.
7
Alarm Cut-Off (ACO)
—Press and release this recessed toggle switch to reset the system alarm speaker and other
audible or visual alarm indicators connected to the CO Alarm interface on the SPIO.
SMC RAID Support
Each SMC is equipped with a hard disk, commonly referred to as a Small Form Factor (SFF) disk.
Important:
The hard disk is not physically accessible. Disk failure constitutes an SMC failure.
If there is a redundant SMC in the chassis, the standby disk mirror the disk in the active SMC, forming an active
Redundant Array of Inexpensive Disks (RAID).
HD RAID ids configurable via CLI commands. RAID control mechanisms allow xDR charging data to be written to the
hard disks on both the active and standby SMCs for later upload to a suitable local or remote storage server.
Event logs related to disk and RAID include disk name, serial number and RAID UUID for reference. They are
generated at the Critical, Error, Warning, and Informational levels.
Event logs at the Critical level are generated for service-affecting events such as:
RAID failure, including failures during runtime and various cases of initial RAID discovery and disk partition
failures
File system failure when the system fails to initialize or mount file systems
Network failure for NFS server-related errors
Event logs at the Error level are generated for important failures:
RAID disk failure, including failures during runtime
Internal errors, including forking process failures
Event logs at Warning level are generated for important abnormal cases:
Overwriting a valid or invalid disk partition, RAID image, and file system
RAID construction in progress and possible failure
Low disk space
Files deleted to free up disk space
Event logs at the Informational level are generated for normal situations:
Disk partition completion
RAID discovery results without overwriting
RAID construction completion
RAID disk added or removed
File system initialization
NFS service start
Summary of Contents for ASR 5000 Series
Page 9: ...Contents ASR 5000 Installation Guide ix Spare Component Recommendations 317 ...
Page 10: ......
Page 14: ......
Page 54: ......
Page 64: ......
Page 90: ......
Page 104: ......
Page 122: ......
Page 126: ......
Page 186: ......
Page 194: ......
Page 206: ......
Page 228: ......
Page 276: ......
Page 284: ......
Page 290: ......
Page 300: ...RoHS Compliance Statement Chassis ASR 5000 Installation Guide 300 Chassis ...
Page 301: ...RoHS Compliance Statement Fan Assembly ASR 5000 Installation Guide 301 Fan Assembly ...
Page 303: ...RoHS Compliance Statement Full Product ASR 5000 Installation Guide 303 Full Product ...
Page 304: ...RoHS Compliance Statement Full Product ASR 5000 Installation Guide 304 ...