OPERATION
3-62
Cine-IPM 2K User’s Manual
020-100164-01 Rev. 1 (01/08)
operational, the message indicates the presence of a potentially serious problem that
should be reported to the manufacturer. You can remove the message, but for best
results you should reset the projector—power the projector down and up again with
the
POWER
key.
System Errors
A system
error
message indicates that a serious malfunction has been detected and
must be reported to the manufacturer as soon as possible (see
Status LED Codes
,
below). The projector will no longer operate and must be reset—power the projector
down and up again with the
POWER
key.
Status Display
If the Status Display window on the front of the
Cine-IPM 2K
shows one of the
following messages, you have encountered a likely system error requiring the
attention of a qualified service technician (see
System Warnings
and
System Errors
,
above). Acknowledge and clear the error from presentation level, or try resetting the
Cine-IPM 2K
2 by powering it off and on again, cooling when necessary. Consult
Table 3.4 and contact your dealer if the problem persists.
Table 3.4. System Error Codes
Code
Description
GENERAL
12
Software error. Power off/on. If persists, contact dealer/factory.
13
CRC error in flash ROM. Download new software.
14
Engineering-only programming is complete. Call Christie, replace TIPM.
15
Attempting to download s/w code without being in boot mode
16
Invalid interrupt. Power off/on. If persists, contact dealer/factory.
17
User has forced system to stay in boot mode
18
Attempting to program boot mode without jumper
SENSORS for COOLING
4C
Projector has shut down due to critical error
FAN
51
Fan has failed in
Cine-IPM 2K
10-bit IMAGE PROCESSOR (TIPM)
60
Boot code CRC failed
61
Unable to program the DigMux PLD
62
Unable to program the Control PLD
63
Unable to program the Bubks PLD
64 Unrecognized
ROM
type
65
Write to flash ROM failed
66
General TIPM failure
67
Downloaded code will not fit into ROMs
68
Communication error with scaler on TIPM
DDOM and EEPROM
70
Unable to access EEPROM on DDOM
71
EEPROM on DDOM has been reinitialized
BACKPLANE OR OPTIONAL MODULES
A0
Unable to program the optional interface module
A1
Unable to power the optional interface module
A2
Unable to program the Backplane
A3
Unable to program the Warp Module option (
ChristieTWIST
)
If necessary, try resetting your system by powering it off and on again (cooling if necessary). For
detailed information, monitor the RS232 IN port. Contact dealer/factory if error persists. Only codes
listed should appear in the Cine-IPM 2K window.
Summary of Contents for CineIPM-2K
Page 1: ...CineIPM 2K U S E R S M A N U A L 020 100164 01...
Page 2: ......
Page 26: ......
Page 108: ......
Page 110: ......
Page 112: ...SERIAL COMMUNICATION CABLES C 2 Cine IPM 2K User s Manual 020 100164 01 Rev 1 01 08...
Page 118: ......