INSTALLATION AND SETUP
2-12
Cine-IPM 2K User’s Manual
020-100164-01 Rev. 1 (01/08)
suited for long distances than is RS232 communication. Note that RS422 is
not
compatible with RS232—connecting a RS232-compatible PC to RS422 can damage
the equipment at either end. Consult the documentation provided with your PC if you
are unsure.
The 9-pin RS422 connector is located on the front input panel of the
Cine-IPM 2K
.
When using this port, make sure to set the baud rate to match that of your RS422
controlling device.
Figure 2.16. Connecting Serial Communications via RS422
CAUTION
Do not use an RS422 port unless you are using
equipment with RS422 capability. The voltage levels of
this signal can damage incompatible equipment.
Ethernet Communications
To add the
Cine-IPM 2K
to an Ethernet network with other equipment such as
controllers and other projectors, connect standard CAT5 Ethernet cable between your
Ethernet controller (or hub) and the Ethernet port on the
Cine-IPM 2K
front panel.
NOTES: 1)
Ethernet crossover cable required if connecting directly to a PC only.
2)
Downloading new software to the projector via Ethernet is not supported.