![Canon ImageRunner 4045 Trouble Error Codes List Download Page 93](http://html.mh-extra.com/html/canon/imagerunner-4045/imagerunner-4045_trouble-error-codes-list_57684093.webp)
93
E840-
0001
Fixing Shutter Motor error
The Fixing Shutter HP
Sensor (PS53) failed the
detection at the Fixing
Shutter operation.
1. Check the operation of the Fixing Shutter Gear
(overload, etc.). 2. Check the operation of the
Fixing Shutter Motor (M15) at the initialization
operation of the Fixing Shutter. 3. Check the
detection of the Fixing Shutter HP Sensor (PS53)
(if the Sensor operates normally). 4. Check the
drawer of the Fixing Assembly and the host
machine. 5. Replace the Fixing Upper Unit and the
Fixing Drawer Harness Unit. 6. Replace the Main
Driver PCB (PCB2) (check the fuse (FU11)).
E880-
0001
Controller Fan error
Error in the Main Controller
Cooling Fan (FM4) is
detected.
Connector disconnection, failure of Fan.
E880-
0005
Controller Fan error
Connector disconnection,
failure of Fan.
Error in the HDD Cooling Fan (FM) is detected.
E905-
0001
POD Deck Air Assist Fan
error
[POD Deck Lite] When the
Air Assist Swing Motor fails
to return to the HP although
a specified period of time
has passed
1. Check connector disconnection/improper
connection. => Disconnect and then connect the
connector. Target connector: Deck Lite Controller
J04, J05 BoxDriver J51, J52, J57 2. Replace the
Swing Motor (M3) and the Air Assist Fan (FM1,
FM2, FM3). 3. Replace the Deck Lite Controller
PCB. 4. Replace the BoxDriver PCB.
Code
Description
Remedy
E905-
0002
POD Deck Air Assist Fan
error
[POD Deck Lite] When the
Pickup Motor Cooling Fan is
not locked
1. Check connector disconnection/improper
connection. => Disconnect and then connect the
connector. Target connector: Deck Lite Controller
J30 2. Replace the Motor Cooling Fan (FM4). 3.
Replace the Deck Lite Controller PCB.
E905-
0003
POD Deck Air Assist Fan
error
[POD Deck Lite] When the
Pickup Motor Cooling Fan is
not unlocked
1. Check connector disconnection/improper
connection. => Disconnect and then connect the
connector. Target connector: Deck Lite Controller
J30 2. Replace the Motor Cooling Fan (FM4). 3.
Replace the Deck Lite Controller PCB.
E906-
0001
POD Deck Air Heater error[
POD Deck Lite] Air Heater
high temperature error
When 120 deg C or higher
temperature is detected for
1 second consecutively
1. Check connector disconnection/improper
connection. - > Disconnect and then connect the
connector. Target connector: Deck Lite Controller
J03, J05 BoxDriver J52, J54, J58, J59 2. Replace
the Air Heater. 3. Replace the Deck Lite Controller
PCB