51
the way 1-C-1. Check abrasion of the Slider
Pin. Replace the Slider Pin. 1-C-2. Replace
the Pre-transfer Charging Assembly. 2.
Replace the DC Controller PCB (PCB1).
E067-
0001
Developing high voltage output
leak error
The leak detection signal was
detected 5 times in a row for every
20 msec.
1. Check the connection between the Main
Driver PCB (PCB2) and the High Voltage
Unit. Main Driver side: J112, High Voltage
Unit side: J3098 2. Check the connection
between the Relay PCB (PCB5) and the
High Voltage Unit. Relay side: J519, High
Voltage Unit side: J3099 3. Replace the
Developing Assembly. 4. Check the
connection point of the Developing
Assembly. If it is soiled, clean it. 5. Check
the connection inside of the High Voltage
Unit. Check the connection of the High
Voltage Unit Relay (J3097) and the
Developing High Voltage PCB (J3511). High
Voltage Unit Relay (J3099) and Pre-transfer
Charging PCB (J3545, J3500, J3510) 6.
Replace the Main Driver PCB (PCB2).
E068-
0001
Pre-transfer charging high voltage
output leak error
The leak detection signal was
detected 5 times in a row for every
20 msec.
1. Check the connection between the Main
Driver PCB (PCB2) and the High Voltage
Unit. Main Driver side: J112, High Voltage
Unit side: J3098 2. Check the connection
between the Relay PCB (PCB5) and the
High Voltage Unit. Relay side: J519, High
Voltage Unit side: J3099 3. Replace the Pre-
transfer Charging Assembly. 4. Check the
connection inside of the High Voltage Unit.
Check the connection of the High Voltage
Unit Relay (J3098) and the Transfer High
Voltage PCB (J3544). Check the connection
of the High Voltage Unit Relay (J3099) and
the Pre-transfer Charging PCB (J3545,
J3500) 5. Replace the Main Driver PCB
(PCB2). 6. Replace the Pre-transfer High
Voltage Connector (FM4- 1007). 7. Replace
the Pre-transfer Transformer (Post Charging
Trance) of the High Voltage Unit.
E069-
0001
Transfer high voltage output leak
error
The leak detection signal was
detected 5 times in a row for every
20 msec
1. Check the connection between the Duplex
Driver PCB (PCB4) and the High Voltage
Unit. Check the connection at Duplex Driver
side (J343) and the Transfer High Voltage
side (J3066). Check the connection at