![Canon ImageRunner 4045 Trouble Error Codes List Download Page 7](http://html.mh-extra.com/html/canon/imagerunner-4045/imagerunner-4045_trouble-error-codes-list_57684007.webp)
7
Code
Description
Remedy
E227-
0003
The reader unit power supply
(24V) is faulty.
At the end of a job, the 24V port is
off.
1. Disconnect and then connect the power
supply harness connector.(J504/J3/J114) 2.
Replace the Power Supply PCB (UN1).
E227-
0004
The reader unit power supply
(24V) is faulty
When a load is being driven, the
24V port is off.
1. Disconnect and then connect the power
supply harness connector.(J504/J3/J114) 2.
Replace the Power Supply PCB (UN1).
E240-
0000
Error in controller communication
The serial communication error
such as parity error or overrun
error is constantly detected.
1. Check the Connectors. 2. Replace the
DC Controller PCB (UN2).
E240-
0001
Error in controller communication
The serial communication error
such as parity error or overrun
error is detected while printing.
1. Check the Connectors. 2. Replace the
DC Controller PCB (UN2).
E246-
0001
System error
Contact to the sales companies.
0002
of the CCD home position.
The attempt to detect the home
position fails when the CCD is
moved back.
flexible cable(Reader Controller PCB
(UN4)-Main Controller PCB 2 (UN14)). 2.
Replace the flexible cable. 3. Replace the
CCD HP sensor (S11). 4. Replace the
Polygon Motor (M11). 5. Replace the
Reader Controller PCB (UN4). 6. Replace
the Main Controller PCB 2 (UN14).
E225-
0000
The light intensity of the CCD is
faulty.
The light intensity of the CCD
during shading is under the
specified level.
1. Disconnect and then connect the
flexible cable. 2. Replace the flexible
cable. 3. Replace the CCD Unit. 4.
Replace the Reader Controller PCB
(UN4). 5. Replace the Main Controller
PCB 2 (UN14).
E227-
0001
The reader unit power supply
(24V) is faulty.
At time of power-on, the 24V port
is off.
1. Disconnect and then connect the power
supply harness connector. (J504/J3/J114)
2. Replace the Power Supply PCB (UN1).
E227-
0002
The reader unit power supply
(24V) is faulty.
At the start of a job, the 24V port
is off.
1. Disconnect and then connect the power
supply harness connector.(J504/J3/J114)
2. Replace the Power Supply PCB (UN1).