![Canon ImageRunner 4045 Trouble Error Codes List Download Page 19](http://html.mh-extra.com/html/canon/imagerunner-4045/imagerunner-4045_trouble-error-codes-list_57684019.webp)
19
and cannot move from HP, it is
detected as an error if the same
symptom occurs again after the first
retry.
physically removed. 4. Check if the Shift
Roller Release Sensor (S3) failure
occurs.
E567-
0001
Shift Roller Release Motor fails to
move from HP
At initial rotation, when the Motor
rotates for specified period of time
and cannot move from HP, it is
detected as an error if the same
symptom occurs again after the first
retry
1. Check if the Motor (M5) Connector is
physically removed. 2. Replace the Motor.
3. Check if the Shift Roller Release
Sensor (S3) Connector is physically
removed. 4. Replace the Shift Roller
Release Sensor (S3).
E567-
0002
Shift Roller Release Motor fails to
return to HP
At initial rotation, when the Motor
rotates for specified period of time
and cannot return to HP, it is
detected as an error if the same
symptom occurs again after the first
retry.
1. Check if the Motor (M5) Connector is
physically removed. 2. Replace the Motor.
3. Check if the Shift Roller Release
Sensor (S3) Connector is physically
removed. 4. Replace the Shift Roller
Release Sensor (S3).
E56F-
0001
Entrance Roller Release/Stopper HP
Motor fails to move from HP
At initial rotation, when the Motor
rotates for specified period of time
and cannot move from HP, it is
detected as an error if the same
symptom occurs again after the first
retry.
1. Check if the Motor (M6) Connector is
physically removed. 2. Replace the Motor.
3. Check if the Entrance Roller
Release/Stopper HP Sensor (S5)
Connector is physically removed. 4.
Replace the Entrance Roller
Release/Stopper HP Sensor (S5).
E56F-
0002
Entrance Roller Release/Stopper HP
Motor fails to return to HP
At initial rotation, when the Motor
rotates for specified period of time
and cannot return to HP, it is
detected as an error if the same
symptom occurs again after the first
retry.
1. Check if the Motor (M6) Connector is
physically removed. 2. Replace the Motor.
3. Check if the Entrance Roller
Release/Stopper HP Sensor (S5)
Connector is physically removed. 4.
Replace the Entrance Roller
Release/Stopper HP Sensor (S5).
E571-
0001
Gripper Open/Close Motor fails to
move from HP
At initial rotation, when the Motor
rotates for specified period of time
and cannot move from HP, it is
detected as an error if the same
symptom occurs again after the first
retry.
1. Check if the Motor (M7) Connector is
physically removed. 2. Replace the Motor.
3. Check if the Gripper Arm HP Sensor
(S13) Connector is physically removed. 4.
Replace the Gripper Unit HP Sensor (S7).