![Canon ImageRunner 4045 Trouble Error Codes List Download Page 58](http://html.mh-extra.com/html/canon/imagerunner-4045/imagerunner-4045_trouble-error-codes-list_57684058.webp)
58
Driver PCB (PCB1).
E227-
0001
Power supply (24V) error
24V port is OFF when the
power is turned ON.B
1. Connector disconnection/open circuit of the
Reader Power Supply. 2. Failure of power supply.
E227-
0002
Power supply (24V) error
24V port is OFF when a job
is started.
1. Connector disconnection/open circuit of the
Reader Power Supply. 2. Failure of power supply.
E227-
0003
Power supply (24V) error
24V port is OFF when a job
is ended.
1. Connector disconnection/open circuit of the
Reader Power Supply. 2. Failure of power supply
E227-
0004
Power supply (24V) error
24V port is OFF when
loading.
1. Connector disconnection/open circuit of the
Reader Power Supply. 2. Failure of power supply.
E227-
0101
Power supply (24V) error
24V port is OFF when the
power of DADF is turned
ON.
1. Connection error between the DADF Driver
PCB (PCB1) and the Reader Controller PCB
(PCB1). 2. Connector disconnection/open circuit
of the Reader Power Supply. 3. Failure of power
supply.
E227-
0102
Power supply (24V) error
24V port is OFF when a job
is started in the DADF.
1. Connection error between the DADF Driver
PCB (PCB1) and the Reader Controller PCB
(PCB1). 2. Connector disconnection/open circuit
of the Reader Power Supply. 3. Failure of power
supply.
E227-
0103
Power supply (24V) error
24V port is OFF when a job
is ended in the DADF.
1. Connection error between the DADF Driver
PCB (PCB1) and the Reader Controller PCB
(PCB1). 2. Connector disconnection/open circuit
of the Reader Power Supply. 3. Failure of power
supply.
E240-
0000
Communication error
between Main Controller and
DC Controller
Communication error occurs
between the CPU of the
Main Controller PCB and the
DC Controller PCB (PCB1).
1. Check the connection of the Main Controller
PCB and the DC Controller PCB (PCB1). Main
Controller side: J712, DC Controller side: J442 2.
Replace the DC Controller PCB (PCB1). 3.
Replace the Main Controller PCB.
E240-
0001
3 minutes passed with
pickup request waiting status
It was detected that 3
minutes passed with pickup
request waiting status.
1. Check the connection of the Connector. 2.
Check the connection of the Sub PCB in the Main
Controller PCB 1 Box. 3. Check the connections
of the DC Controller PCB and the Main Controller
PCB 1. Replace the PCB(s) if necessary.
E240-
3 minutes passed with image 1. Check the connection of the Connector. 2.