skip.
IAT >=
err-
thresh:
The Inter-packet Arrival Time exceeds
the error threshold
Default: Disabled, severity
Error
IAT >=
warn-
thresh:
The Inter-packet Arrival Time exceeds
the warning threshold
Default: Disabled, severity
Warning
MLR >=
err-
thresh:
The Media Loss Rate exceeds the
error-threshold
Default: Enabled, severity
Error
MLR >=
warn-
thresh:
The Media Loss Rate exceeds the
warning-threshold
Default: Disabled, severity
Warning
TTL
changed:
The Time-To-Live field is changing
Default: Enabled, severity
Error
TOS
changed:
The Type-Of-Service field is changing
Default: Enabled, severity
Error
Multiple
mcast
sources:
There are multiple multicast sources
Default: Enabled, severity
Error
Mcast
source
changed:
The multicast source changed to one
of the valid multicast sources specified
by the operator.
Default: Enabled, severity
Error
Bitrate
overflow:
The stream bitrate exceeds the
maximum bitrate Ethernet threshold
value specified by the operator.
Default: Enabled, severity
Error
Bitrate
underflow
:
The stream bitrate goes below the
minimum bitrate Ethernet threshold
value specified by the operator.
Default: Enabled, severity
Error
FSM alarms
Full service
monitoring:
Enable to view all FSM alarms.
Default: Enabled, severity
Major
ETR (ETR 290) alarms
TS Sync:
No TS Sync
Default: Enabled, severity
Major
Sync byte:
Sync byte error
Default: Enabled, severity
Major
PAT:
Program Association Table error
Default: Enabled, severity
Major
PROBE USERS' MANUAL VERSION 5.0
2014 © BRIDGE Technologies Co AS - Bentsebrugata 20 - N-0476 Oslo, Norway - tel: +47 22 38 51 00
-
www.bridgetech.tv
58