about events in the specified transport stream.
The event information list parameters:
Time:
When the event occurred.
Service ID:
The ID of the service for which the event applies.
Service name:
The name of the service for which the event applies.
PID:
The PID carrying the SCTE 35 information. A service can have
multiple SCTE 35 PIDs signaled in the PMT table.
Splice command:
The type of the splice command.
Event ID:
Id of the specific event.
Canceled
indicator:
If set it indicates that this splie message cancels a previously
sent splice message.
Switch mode:
Specifies whether it is a splice in (switch to local content/ads) or
splice out event (switch back to the audio/video in the stream).
Splice mode:
Specifies whether the splice message applies to the entire
serivice (Program splice mode) or individual PID(s).
Duration:
The time when a splice occurred to its end.
Tier:
Specifies which tier group are to use this splice message.
Multiple splice messages can be sent addressed to different tier
groups to allow switching at different times.
When pressing the information button for a specific event a new window will popup
with detailed information about the event. The popup will show a log of the SCTE 35
events signaled for the specified transport stream. Splice NULL messages are not
logged.
PROBE USERS' MANUAL VERSION 5.0
2014 © BRIDGE Technologies Co AS - Bentsebrugata 20 - N-0476 Oslo, Norway - tel: +47 22 38 51 00
-
www.bridgetech.tv
135