ETR Thresholds - Priority 3:
NIT:
Enable or disable alarming of Network Information Table errors.
Only relevant when DVB mode is selected.
NIT - Maximum
interval Actual
(ms):
The maximum allowed section repetition interval for the NIT
Actual table.
Default: 10 s
NIT - Maximum
interval Other
(ms):
The maximum allowed section repetition interval for the NIT
Other table.
Default: 10 s
NIT - Require
network id:
If enabled the probe will require that the network ID found in the
NIT matches the configured value.
Default: Disabled
NIT - Require
original
network id:
If enabled the probe will require that the original network ID
found in the NIT matches the configured value.
Default: Disabled
NIT - Min. num.
transport
streams:
The minimum number of transport streams that must be
present in the NIT. Set to 0 to disable this check.
Default: 0
NIT - Cable
descriptor:
If set to 'Required' an alarm will be generated if a Cable
descriptor is not present in the NIT for the monitored frequency.
Similarly if set to 'Not allowed', an alarm will be generated if the
Cable descriptor is present.
Default: Optional
NIT - Satellite
descriptor:
If set to 'Required' an alarm will be generated if a Satellite
descriptor is not present in the NIT for the monitored frequency.
Similarly if set to 'Not allowed', an alarm will be generated if the
Satellite descriptor is present.
Default: Optional
NIT - Terrestrial
descriptor:
If set to 'Required' an alarm will be generated if a Terrestrial
descriptor is not present in the NIT for the monitored frequency.
Similarly if set to 'Not allowed', an alarm will be generated if the
Terrestrial descriptor is present.
Default: Optional
NIT - Compare
with reference
NIT:
If enabled the NIT will be compared with the NIT on the
reference frequency, and an alarm will be generated if a
mismatch is found. The first frequency in the tuning list will be
used as the reference frequency. Both the CRC values of the
different sections and the number of sections must be identical.
Default: Disabled
SI Repetition
Enable or disable alarming of SI Repetition Rate errors.
PROBE USERS' MANUAL VERSION 5.0
2014 © BRIDGE Technologies Co AS - Bentsebrugata 20 - N-0476 Oslo, Norway - tel: +47 22 38 51 00
-
www.bridgetech.tv