threshold template was assigned to a stream being monitored, the new threshold for
that stream will default to the predefined
Default
threshold template.
The PID threshold template has the following settings:
Edit PID Threshold:
Name:
The name of the PID threshold template
Description:
Text field that should contain a meaningful description of the
threshold template
PID Threshold Parameters:
Selection:
The user selects if the requirements should apply for a specific PID
or for all PIDs of a specified type. Note that the PID type detection
depends on correct PSI/SI/PSIP signalling.
PID:
The PID for which the specified requirements apply. If a PID type is
selected in the 'Match' column this field will update to read N/A
when the
Apply changes
button is clicked.
Description:
A text field describing the PID or PID type requirement
Require
pres.:
If this field is checked an alarm will be raised provided that the
specified PID is not present in the transport stream. Note that this
check is only available for specified PIDs and not for PID types.
Monitor min
BW:
An alarm is raised if the PID bandwidth goes below the specified
minimum bandwidth (bandwidth in kbit/s or Mbit/s) and monitoring
is enabled.
Monitor max
BW:
An alarm is raised if the maximum PID bandwidth specified is
exceeded (bandwidth in kbit/s or Mbit/s) and monitoring is enabled.
Ignore CC:
Select a scheduling template different from 'Never' for the probe to
ignore CC errors for the specified PID or PID type.
Ignore
missing:
Select a scheduling template different from 'Never' for the probe to
ignore that the specified PID or PID type is signalled in PSI but
missing in the stream.
Ignore
unref.:
Select a scheduling template different from 'Never' for the probe to
ignore that the specified PID is present in the stream but
unreferenced in PSI.
Ignore all:
Select a scheduling template different from 'Never' for the probe to
ignore all errors for a specified PID or PID type.
Scrambling:
An alarm will be raised provided that the specified PID is scrambled
when 'require clr' has been selected. Similarly an alarm will be
raised if the specified PID is clear when 'require scr' has been
selected. The default setting is to ignore whether the PID or PID
type is scrambled or not.
PROBE USERS' MANUAL VERSION 5.0
2014 © BRIDGE Technologies Co AS - Bentsebrugata 20 - N-0476 Oslo, Norway - tel: +47 22 38 51 00
-
www.bridgetech.tv
156