The SAT threshold parameters are:
SAT Threshold - Edit:
Name:
A text field describing the threshold template
Maximum post FEC
BER:
Threshold level for bit error ratio after forward error
correction
Maximum signal to
noise ratio:
Threshold level for signal to noise ratio (dB)
Minimum signal
strength:
Minimum threshold level for signal strength.
This is a measure of the stream signal power. It is
expressed according to the level mode selection made in
the
Setup - ETR
view:
dBm: in decibels relative to a reference value of
1
mW
dBuV: in decibels relative to a reference value of
1
µ V
dBmV: in decibels relative to a reference value of
1
mV
Maximum signal
strength:
Maximum threshold level for signal strength.
This is a measure of the stream signal power. It is
expressed according to the level mode selection made in
the
Setup - ETR
view:
dBm: in decibels relative to a reference value of
1
mW
dBuV: in decibels relative to a reference value of
1
µ V
dBmV: in decibels relative to a reference value of
1
mV
PROBE USERS' MANUAL VERSION 5.0
2014 © BRIDGE Technologies Co AS - Bentsebrugata 20 - N-0476 Oslo, Norway - tel: +47 22 38 51 00
-
www.bridgetech.tv
212