ETR Thresholds - Priority 1:
TS sync:
Enable or disable alarming of no signal error (TS sync loss)
Sync byte:
Enable or disable alarming of sync byte errors
PAT:
Enable or disable alarming of Program Association Table errors
PAT - Maximum
interval (ms):
The maximum allowed section repetition interval for the PAT
table.
Default: 500 ms
PAT - Minimum
number of
services:
The minimum number of services that must be present in the
PAT. Set to 0 to disable this check.
Default: 0
PAT - Allowed
Transport
Stream IDs:
When this field is left blank all TS IDs are considered valid. If
one or more TS IDs are specified (separated by commas or as a
range) only these IDs are considered valid, and any other TS ID
will trigger an alarm.
Example of a valid field: '100-120, 300,320'
Continuity:
Enable or disable alarming of Continuity Counter errors
PMT:
Enable or disable alarming of Program Map Table errors
PMT - Maximum
interval (ms):
The maximum allowed section repetition interval for the PMT
tables.
Default: 500 ms
PMT - Minimum
number of
components:
The minimum number of components that must be present in
all services. Set to 0 to disable this check.
Default: 0
PMT - Require
language
descriptors:
If enabled it requires a language descriptor to be present for all
audio components signalled in the PMT.
Default: Disabled
Missing PID:
Enable or disable alarming of missing PID errors
Note that errors affecting individual PIDs may be effectively masked by creating
suitable PID threshold templates that are associated with these PIDs. This is
particularly useful for PIDs affected by continuity counter errors, missing PID errors
and unreferenced PID errors.