ETR Thresholds - Other checks:
CA system checks:
Enable or disable alarming of Conditional Access
System errors.
CA system checks -
Maximum ECM interval
(ms):
The maximum allowed ECM repetition interval
Default: 500 ms
CA system checks -
Maximum ECM change
period (ms):
The maximum time allowed between ECM changes
Default: 25000ms
CA system checks -
Minimum avg. EMM bitrate
(bps):
The minimum allowed average EMM bitrate
Default: 1000 bps
CA system checks - EMM
bitrate average period (s):
The averaging period used to calculate EMM bitrate.
Note that the average period must be at least 20s
less than the round-robin tuning period, e.g. with a
round-robin tuning period of 70s the maximum EMM
bitrate average period is 50s.
Default: 10s
CA system checks -
Maximum control word
period (ms):
The maximum allowed control word period (the
maximum time that can go by without a change in
the scrambling control bits for scrambled PIDs)
Default: 25 000 ms
PID checks:
Enable or disable alarming of PID minimum bitrate,
maximum bitrate, presence errors and
scrambling/clear required.
Service checks:
Enable or disable alarming of service minimum
bitrate, maximum bitrate, service presence,
scrambling/clear required, service type, service
name and service ID errors. Requirements are
specified in the service threshold template
associated with the stream.
Service checks - Only
allow services listed in
service template:
Check this box to enable service ID checks against
the service ID list specified in the service threshold
template associated with the stream.