6.17 Setup
6.17.1 Setup - Params
The Parameters page contains the following settings:
Various
Probe-name:
Each probe can be assigned a user defined name. This name
is shown in the
Summary page
which is the probe default
page. The probe name is displayed in the browser's title line.
Probe location:
The probe location is part of the probe's MIB, and this
parameter is relevant for SNMP use only. The probe location is
displayed in the browser's title line.
Enable
thumbnails:
For high bitrates (above 700 Mbit/sec) the probe may feel
more responsive if thumbnail picture generation is switched
off. This does not affect the accuracy of the measurements.
Alarms
Freeze log when
full:
When enabled the alarm list will freeze when full (an event
will show that it is full). When the list is full new alarms are
ignored until
Clear alarms
is pressed.
This can sometimes be useful if a unit is placed
unattended.
Treat events as
alarms:
When enabled each event is treated as an alarm that is
active for 5 seconds. This may be useful when reporting to
external systems that do not support events but only active
or cleared alarms. This setting affects the local alarm lists
and SNMP traps.
PROBE USERS' MANUAL VERSION 5.0