The Service threshold template has the following settings:
Edit Service Threshold:
Name:
The name of the ETR threshold template
Description:
Text field that should contain a meaningful description of the
threshold
Service Threshold Parameters:
Selection:
The user selects if the requirements should apply for a specific
service ID, for all services of a specified type or for a service with
a specified service name. Note that the service type detection
depends on correct PSI/SI/PSIP signalling.
ID:
The service ID value
Monitor
name:
A text string may be specified that should match the service name
of the associated service ID, as analysed from the received SDT.
Note that the check is case sensitive. An alarm will be raised if
there is not a perfect match.
Require
presence:
If this field is checked an alarm will be raised provided that the
specified service is not present in the stream. This check only
requires that the service is present in the PAT, the other ETR
checks will give alarms if there are other problems with the
service, such as missing PMT or missing components. Note that
this check is only available for specified services and not for
service types.
Monitor min
BW:
If enabled an alarm is raised provided that the minimum service
bandwidth goes below the specified bandwidth (in kbit/s or
Mbit/s).
Monitor max
BW:
If enabled an alarm is raised provided that the maximum service
bandwidth specified (in kbit/s or Mbit/s) is exceeded.