6.8.5 Ethernet - FSM (requires AET-OPT)
Full Service Monitoring (FSM) allows easy validation of any server reachable by the
probe via Ethernet. The servers may be probed by either sending an ICMP Echo
Request packet (also known as Ping) or performing an HTTP Get request.
Up to 10 services may be defined and each service will be checked at regular
intervals. Any errors will be logged. An error is defined as no reply within 5 seconds for
the Ping option or no, or incorrect, reply within 5 seconds for the HTTP option. If there
are more consecutive errors than a fails threshold value an alarm will be raised.
FSM - Monitor
The following parameters are continuously monitored for each service:
Status:
Current alarm status. Red = active alarm, Green=No alarm
Name:
User defined service name
Protocol:
Type of protocol. HTTP or Ping
IP address:
IP address. Must be numeric, host name is not accepted
Ok:
Total number of valid checks
Fail:
Total number of invalid checks
Max:
Maximum response time recorded
Min
Minimum response time recorded
Current:
The current (most recent) response time
Timer:
Button to reset and immediately restart the service
State:
Current state of the service. The states are: "Disabled",
"Waiting to send", "Waiting for reply", "Got reply" and "Reset".
PROBE USERS' MANUAL VERSION 5.0
2014 © BRIDGE Technologies Co AS - Bentsebrugata 20 - N-0476 Oslo, Norway - tel: +47 22 38 51 00
-
www.bridgetech.tv
107