
Multi-edit functionality allows editing several VBC thresholds simultaneously. Highlight
the list entries that should be edited and click the
Edit selected
button.
VBC thresholds
Name:
The name of the VBC threshold template
No signal:
Number of seconds with 'No signal'
RTP error:
Number of seconds with RTP packet drops. This measurement
will be zero unless the stream is encapsulated in RTP headers
MLR error:
Number of seconds with packet drops in the TS layer (seconds
when media loss rate is non-zero). This is equal to the number
of error seconds with CC errors.
IAT error:
Number of seconds when the inter-packet arrival time exceeds
the threshold
Max bitrate
error:
Number of seconds the bitrate can exceed the error-threshold
before a VBC alarm is generated
Min bitrate error:
Number of seconds the bitrate can fall below the error-
threshold before a VBC alarm is generated
ETR Pri 1 errors:
Number of seconds with ETSI TR 101 290 Priority 1 alarms
PROBE USERS' MANUAL VERSION 5.0
2014 © BRIDGE Technologies Co AS - Bentsebrugata 20 - N-0476 Oslo, Norway - tel: +47 22 38 51 00
-
www.bridgetech.tv
235