38/132 Installation
Bosch Rexroth AG
, SYEPS series 1X, RE 30201-B/07.2014
3.
Drain the SYEPS punching system completely prior to installing it in order to
prevent mixing with the fluid used in the machine.
7.5.1 Mounting the SYEHL punching axis mechanically
Mount the SYEHL punching axis by screwing in 6 bolts in mounting bores M20-30 and
tightening them to the tightening torque specified on the installation drawing. The
mounting orientation is vertical as shown on the drawing below.
For dimensional details, see installation drawing.
Fig. 10: Mounting bores of the SYEHL punching axis
The installation of the T-line on the SYEHL punching axis is shown on Fig. 10 on page
38.
7.5.2 Mounting the SYEHL punching axis hydraulically
All ports to be connected are marked with plastic plugs. An exception is the tank line
port. It is plugged with an SAE plug.
The LP, HP, T, Y, L and D ports (D port not on version Standard 600) must be
connected.
4xM10 - mechanical
connection of plunger
extension
Bore Ø12 H11 - 25 mm deep,
for locating pin
6 x M20-35/45 deep max.
tightening torque 400 Nm