Appendix E Troubleshooting
Failure Possible
reasons
After plugging in power, turning on the power switch,
“POWER” light in front Panel does not turn on, and fan
does not work.
1) Power cable is broken.
2) Power supply is broken.
After plugging in power, turning on the power switch,
“POWER” light in front panel turn to green while fan
does not work.
1) Front panel cable is
broken.
2) Fan is broken.
After plugging in power, turning on switch, “POWER”
light turn to green, the indicator lights in the panel turn
on at the same time, but fan does not work.
The ATX plug in main board is
not well plugged in.
DVR continuously reboots after start up, and makes a
sound like “di” every 10 seconds.
1) Upgrade the wrong
firmware
2) Compression board has
problems.
3) Main board has problems.
There are no images in the monitor connected with
VOUT after DVR is started.
1) The cable connected with
the monitor is broken.
2) Real board of DVR has
problems.
3) Main board of DVR has
problems.
Cannot find the hard disk in reboot process.
1) Hard disk cable is broken.
2) The power cable of hard
disk is not connected.
3) Hard disk is broken.
No reponse in HyperTerminal interface.
1) Baud rate is not matched.
2) RS-232 cable is broken.
3) Serial port of PC is broken.
4) RS-232 port of DVR is
broken.
DVR can not control PTZ through RS-485
port.
1) RS-485 cable is not
connected correctly or
broken.
2) PTZ parameters error.
3) RS-485 port of DVR is
broken.
Client software can not view DVR live image.
1) Network is error.
2) Connect wrong DVR
(wrong IP, port number,
132
Summary of Contents for SVR-80xx-S series
Page 11: ...1 3 Typical Application 11 ...
Page 15: ...6 Check all connections and mount back the metal cover of the DVR 7 Switch on the DVR 15 ...
Page 26: ...How to exit menu Press PREV or ESC key to exit menu and return to preview mode 26 ...
Page 53: ...In this case press ENTER to return password edit box and input new password again 53 ...
Page 59: ...59 ...
Page 69: ...69 ...
Page 108: ...Step 6 You can preview the image of 192 1 0 2 by using client end software 108 ...
Page 124: ...In the formula a means alarm occurrence rate 124 ...
Page 126: ...The corresponding relationship of cross cable 126 ...
Page 136: ...Suggestions 136 ...