66
Chapter6 P3
V/F
control parameter
the P4 group and PC group parameters to determine the output voltage.
6: When the simple PLC voltage source is a simple PLC, you need to set the PC group
parameters to determine the given output voltage.
7: PID: The output voltage is generated according to the PID closed loop. For details,
see the introduction of the PA group PID.
8: Communication reference The voltage is given by the host computer through
communication.
When the above voltage source is selected from 1 to 8, 0 to 100% corresponds to the output
voltage 0V to the motor rated voltage.
P3-15
VF separation voltage
acceleration time
0.0s
~
1000.0s
Default
:
0.0s
P3-16
VF separation voltage
deceleration time
0.0s
~
1000.0s
Default
:
0.0s
The VF separation rise time refers to the time required for the output voltage to change
from 0V to the rated voltage of the motor. As shown in Figure 6-5
:
Actual acceleration time
Actual deceleration time
Set deceleration time
Set acceleration time
Target voltage
Motor rated voltage
Output voltage
t1
t2
6-5 V/F Separation diagram