116
Chapter 6 PC mutiple Multi-segment instruction,PLC
Pb-00
Swing
frequency
setting method
0
:
Relative to the center frequency 1:
relative to Maximum frequency
Default
:
0
This parameter is used to determine the reference amount of the swing.
0
:
Relative to the center frequency (P0-07 frequency source), it is a variable swing
system. The swing varies with the center frequency (set frequency). 1: Relative to the
Maximum frequency (P0-10), for a fixed swing system, the swing is fixed.
Pb-01
Swing frequency range
0.0%
~
100.0%
Default
:
0.0%
Pb-02
Kick frequency
amplitude
0.0%
~
50.0%
Default
:
0.0%
This parameter is used to determine the value of the swing value and the kick frequency.
When the swing is set relative to the center frequency (PB-00 = 0), the swing AW =
frequency source P0-07 × swing amplitude PB-01. When setting the swing relative to the
Maximum frequency (PB-00 = 1), the swing AW = Maximum frequency P0 - 10 × swing
amplitude PB-01.
The amplitude of the kick frequency is the percentage of the frequency of the kick
frequency relative to the swing when the swing frequency is running, that is, the burst
frequency = swing AW × kick frequency amplitude PB-02. If the swing is selected relative
to the center frequency (PB-00 = 0), the burst frequency is the change value. If the swing
is selected relative to the Maximum frequency (PB-00 = 1), the burst frequency is a fixed
value.
The swing frequency is limited by the upper and lower frequencies.
Pb-03
Wobble cycle
0.1s
~
3000.0s
Default
:
10.0s
Pb-04
Swing frequency
triangle wave rise time 0.1%
~
100.0%
Default
:
50.0%
Wobble cycle: The time value of a complete wobble cycle.
The triangular wave rise time coefficient PB-04 is the time percentage of the triangular
wave rise time relative to the swing frequency period PB-03. Triangle wave rise time =
swing frequency period PB-03 × triangle wave rise time coefficient PB-04, in seconds.
Triangle wave fall time = swing frequency period PB-03 × (1 - triangular wave rise time
coefficient PB-04), in seconds.
Pb-05
Set length
0m
~
65535m
Default
:
1000m
Pb-06
Actual length
0m
~
65535m
Default
:
0m
Pb-07
Pulse
number per
meter
0.1
~
6553.5
Default
:
100.0