Chapter 6 P4 input terminal
75
K1
K2 Run
1
0
Forward
1
1
Reverse
0
0 stop
0
1
stop
Terminal
command mode
P4-11
1
Two-line 2
X1
P4-00
1
Run enable
X2
P4-01
2
Positive and negative
direction
Figure 6-7 Two-wire mode 2
2
:
Three-wire control mode 1, this mode X3 is the enable terminal, and the
direction is controlled by X1 and X2 respectively. Terminal function settings are as
follows
:
Terminal
Function code Setting value
Description
Terminal
command mode
P4-11
2
Three-wire type 1
X1
P4-00
1
Forward running (X1)
X2
P4-01
2
Reverse run (X2)
X3
P4-02
3
Three-wire operation
control
X2 Reverse
(
open
)
X3 Stop
(
closed
)
Stop
SB1
Reverse SB3
Forward SB2
X1 Run
(
open
)
COM
Figure 6-8 Three-wire control mode 1
As shown in the figure above, in the control mode, when the SB1 button is closed,
press the SB2 button to turn the inverter forward. Press the SB3 button to reverse the
inverter. When the SB1 button is turned off, the inverter stops. During normal start-up
and operation, it is necessary to keep the SB1 button closed. The commands of the SB2
and SB3 buttons are valid at the end of the closing action. The running status of the
inverter is based on the last button action of the three buttons.
3: Three-wire control mode 2, the X3 enable terminal of this mode, the running
K2
X1 Running
X2
Positive
and
negative direction
COM
K1