Chapter 5 Function parameter
28
2: Forward and reverse switching 3: Forward
rotation
4: Reverse jog
P7-02
Function selection
0: Only the button command under the
keyboard command is valid.
1: Button stop is valid under any
circumstances
1
〇
P7-03
STOP/RESET button
0000~FFFF
Bit0: Operating frequency 1 (Hz) Bit1:
Setting frequency (Hz)
Bit2: Bus voltage (V) Bit3: Output voltage
(V)
Bit4: Output current (A) Bit5: Output
power (kW)
Bit6: Output torque (%) Bit7: Input status
Bit8: Output Status Bit9: AI1 Voltage (V)
Bit10: AI2 voltage (V) Bit11: AI3 voltage
(V)
Bit12: Count value Bit13: Length value
Bit14: Load speed display Bit15: PID setting
1F
〇
P7-04
LED
operation
display parameter 2
0000~FFFF
Bit0: PID feedback Bit1: PLC stage
Bit2: Pulse input frequency (kHz)
Bit3: Operating frequency 2 (Hz)
Bit4: remaining running time
Bit5: AI1 pre-correction voltage (V)
Bit6: AI2 pre-correction voltage (V)
Bit7: AI3 pre-correction voltage (V)
Bit8: Line speed Bit9: Current power-on time
(Hour) Bit10: Current running time (Min)
Bit11: PULSE input pulse frequency (Hz)
Bit12: Communication setting value Bit13:
Encoder feedback speed (Hz) Bit14: Main
frequency X Display (Hz) Bit15: Auxiliary
frequency Y display (Hz)
0
〇
P7-05
LED stop display
parameters
0000~FFFF
Bit00: Set frequency (Hz) Bit01: Bus voltage
(V)
Bit02: X input status Bit03: Output status
Bit04: AI1 voltage (V) Bit05: AI2 voltage (V)
Bit06: AI3 voltage (V) Bit07: count value
Bit08: Length value Bit09: PLC stage
Bit10: Load speed Bit11: PID setting
Bit12: PULSE input pulse frequency (kHz)
33
〇
P7-06
Load speed display
factor
0.0001
~
6.5000
1.0000
〇
P7-07
Module heat sink
temperature
0.0
℃~
100.0
℃
-
×
P7-08
Product ID
-
-
×
P7-09
Cumulative running
time
0h
~
65535h
-
×
P7-10
Product ID
-
-
×
P7-11
Software
version
number
-
-
×
P7-12
Load speed display
0: 0 decimal place 1:1 decimal place
2: 2 decimal places 3: 3 decimal places
1
〇