Chapter 5 Function parameter
30
P8-19
Frequency detection value
FDT1
0.00Hz
~
Maximum frequency
50.00Hz
〇
P8-20
Frequency detection
hysteresis value (FDT1)
0.0%
~
100.0%
(
FDT1
)
5.0%
〇
P8-21
Frequency arrival detection
width
0.0%
~
100.0%
(
Maximum
frequency
)
0.0%
〇
P8-22
Whether the jump
frequency is effective
during acceleration and
deceleration
0
:
Invalid 1
:
Valid
0
〇
P8-25
Acceleration time 1 and
acceleration time 2 switch
frequency points
0.00Hz
~
Maximum frequency
0.00Hz
〇
P8-26
Deceleration time 1 and
deceleration time 2 switch
frequency points
0.00Hz
~
Maximum frequency
0.00Hz
〇
P8-27
Terminal jog priority
0
:
Invalid 1
:
Valid
0
〇
P8-28
Frequency detection value
FDT2
0.00Hz
~
Maximum frequency
50.00Hz
〇
P8-29
Frequency detection
hysteresis value (FDT2)
0.0%
~
100.0%
(
FDT2
)
5.0%
〇
P8-30
Arbitrary arrival frequency
detection value 1
0.00Hz
~
Maximum frequency
50.00Hz
〇
P8-31
Arbitrary arrival frequency
detection width 1
0.0%
~
100.0%
(
Maximum
frequency
)
0.0%
〇
P8-32
Arbitrary arrival frequency
detection value 2
0.00Hz
~
Maximum frequency
50.00Hz
〇
P8-33
Arbitrary arrival frequency
detection width 2
0.0%
~
100.0%
(
Maximum
frequency
)
0.0%
〇
P8-34
Zero current detection level
0.0%
~
300.0%
100.0% Corresponding motor rated
current
5.0%
〇
P8-35
Zero current detection
delay time
0.01s
~
600.00s
0.10s
〇
P8-36
Output current limit
0.0%
(
Not detecting
)
0.1%
~
300.0%
(
Motor rated
current
)
200.0%
〇
P8-37
Output current overrun
detection delay time
0.00s
~
600.00s
0.00s
〇
P8-38
Arbitrary arrival current 1
0.0%
~
300.0%
(
Motor rated
current
)
100.0%
〇
P8-39
Arbitrary current 1 width
0.0%
~
300.0%
(
Motor rated
current
)
0.0%
〇