Chapter 3 Wiring
12
connected to the common ground.
Please refer to the following illustration:
(a) correct
(
b
)
Not recommended
(
c
)
Incorrect
3-4 Control circuit terminal description
classifi
cation
mark
Terminal name
Terminal description and
Default Setting
Multi-
function
input
X1
Multi-function
input terminal 1
Default Setting
:
Forward
X2
Multi-function
input terminal 2
Default Setting
:
Forward Jog
X3
Multi-function
input terminal 3
Default Setting
:
Fault reset
X4
Multi-function
input terminal 4
Default Setting
:
Multi-speed 1
X5
Multi-function
input terminal 5
Default Setting
:
no function
X6
Multi-function
input terminal 6
Default Setting
:
Multi-speed 2
,
Can be used
as a high speed pulse input
COM
Public terminal
Multi-function input common, +24V power
supply reference ground
Analog
input
AI1
Analog input 1
0~10V input
AI2
Analog input 2
0~10V/0~20mA input (J2 optional)
+10V
Analog
power
supply
+10V DC 10mA
(
Potentiometer 3~5K
)