Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 189 of 252
Status: 19.03.2021
Time characteristics of
the “
SET/Q
UIT“
process:
k
k+1
k+2
k+3
k+4
QUIT
SET
SOS_Enable
Assumption
position
Save position
Processing cycles
The sequence is time-monitored and triggers an ALARM if the expected values are exceeded.
ATTENTION
: The maximum time frame is 3 seconds!
Position tolerance
Tolerance value for the TeachIn position.
cw (enabled) = PosAct. + Stop_distance
act
. < targ position tolerance
ccw (enabled) = PosAct. - Stop_distance
act
. < target_pos
–
position tolerance
NOTICE:
If the TeachIn function is used, the monitoring limit is enlarged by the position tolerance value.
Without the TeachIn function, the position tolerance value is zero.
For the input
“Setting”
either a push-button switch must be used, or two position switcheslinked
with AND must be assigned to the input. When the position tolerence is determined, the maximum
permissible position must be considered. =>maximum position tolerance value = maximum
position in the direction of travel
–
Teach-in position.
Parameters of the SOS dialogue:
cf. SOS function