Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 176 of 252
Status: 19.03.2021
The function to monitor position, speed and shut-off is enabled only after the successful
configuration of an encoder. After the encoder has been successfully configured, the respective
functions can be inserted, if the SCU-module has resources available for this purpose. After all
resources have been used, the menu option for the corresponding function block is deactivated.
4.13.5.2.1.
Overview of safety modules
Module
Amount Use
Single
axle
cascading Reset
FDB
8
RUN, RUN internal
No
No
No
EDM
16
RUN, RUN internal
No
No
YesYes
SBR
2
Procession on GBox
--
--
--
SRS
12
RUN, RUN internal
Yes
No
No
SRX
48
RUN
Yes
Non
No
SEL
16
RUN
Yes
Yes
Yes
SLP
12
RUN
Yes
No
Yes
SCA
48
RUN
Yes
Yes
No
SSX
18
RUN
Yes
No
Yes
SLI
12
RUN
Yes
No
Yes
SDI
12
RUN
Yes
No
Yes
SLS
48
RUN
Yes
Yes
Yes
SOS
16
RUN
Yes
Yes
Yes
ECS
12
RUN
Only on GBox
Yes
No
Yes
MPM
2
RUN
Yes
No
Yes
If the shut-off shall be displayed externally by a monitoring function, e. g. a control unit, an auxiliary
output can be used for this purpose.
If “1” has been signalled to the outputs, while the monitoring
functions are in the “OK”
status, the result must be negated for feedback according to the following
example.
Cascading
In case of safety modules with cascading, subsequently, another safety modul can be triggered,
without losing a system cycle.
With safety modules without cascading, 1 cycle must be added for response time.