EOS (External Offset Setup)
Setting of the encoder positions to the configured position value
Amount:
cf. the chapter
“Safety functions”
Access-ID:
identrification of the function element
Function:
Calculation of a shift value for position encoders for a position encoder on the basis of a settable
setting postion on the basis of the current encoder position. By the activation of the EOS function,
the current position value is adjusted to a preset paranetrizable value by the revaluation and the
setting of the shift value.
Input:
position signal X by the encoder interface.
Selection module / axis and encoder
RESET function: no reset necessary
Operation:
The activation of this function starts with a rising edge at the input of this
function.
The EOS function can be used only afterthe activation position processing and
after setting of the absolute encoder (e. g. SSI encoder) in the selected encoder
channel.
Parameters:
Then, this module can be set in the function block. For this purpose, the sensor
channel is selected via the axis and the encoder number. The specification of
the preset value happens in the physical unit that has been selected for the
measuring distance.