Encoder position:
shows the position values for encoder A and encoder B, transmitted by the
encoders. You can mark the current position with
the “
Snapshot
” button
. The program shows the
distance parameters from the registered position.
Encoder interface:
displays the voltage difference of the output modules and the status of the
input jumpers in the encoder interface. If one of the stress values is 0, the encoder is defective or
not connected. The value of the input jumper must be interpreted differently.
With incremental encoders:
0: = jumper OK
1: = error
With SSI encoders:
0: = receiver operation
1: = SSI encoder operation
Alarm mute:
displays the active functions for alarm mute.
Function block:
allows the selective monitoring of previously selected function blocks. To select
function blocks from the work surface for diagnosis, use the button
„
Add selected function block(s)
to diagnosis
”
.
Via these tab the logic states “0” or “1” can be displayed in the function chart.