Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 211 of 252
Status: 19.03.2021
Figure 167 properties window of Multiaxes position monitoring
Position of the Master
Selection (mode) between Axis and Functional. Currently onlyone axis is supported. The supported
axis is the referential axis for the comparison with the other axes.
Number of axes
Number of comparative axes
1…12
Permanent
If the function is enabled, it is permanently enabled.
Type
Selection between:
•
Absolute: onfiguration of the offset of the referential axis to the comparative axis
•
Incremental: calculation of the offset of the referential axis to the comparative axis
with rising activation of the function.
NOTICE:
If incremental is used, the activation of
“Permanent” [permanent] cannot be
used.
Output
Selection between:
•
Single: result of comparison of every axis as group feedback
•
PeraAxis: result of comparison of every individual axis