Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 130 of 252
Status: 19.03.2021
Figure 111 Properties window, master property
SMMC cycle time
Cycle time of the SMMC communication in [ms]
[16ms
…
4096ms]
SMMC Timeout
Timeout time of the SMMC communikation in [ms]
[32ms
…
8192ms]
Name
Free input possible for users
Individual Master configuration
After a click on every Master device in the SMMC network, the properties with which these devices
can be configured individually appear in the properties window.
Figure 112 Tab "global network"
SMMC serial number
–
entry field. Here, the serial number of the selected device must be
entered.
SMMC Master adress
–
This is the address of the device in the SMMC network. The SMMC
Master device has the address 0. The ranking in the plan and the Master address are
interconnected. The first device (from top to bottom) is the Master, and has the addres 0. The
second device has the address 1, the third device has the address 2, and the last device has the
address 3. If the user changes the ranking of the devices in the global network via Drag & Drop,
the Master address changes according to the above principle (first device = Master address 0,
etc.).
By clicking on the Master device in the browser with the right mouse button, this device can be
selected as Master. After this device has been selected as Master, it appears in first position in the
global network, and the other devices are pushed downward, and the addresses of the Masters
change.