Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 102 of 252
Status: 19.03.2021
Information:
The symbol addresses shown in the list are also used for compilation and itn the
validation report.
Tip:
With the
command “Select all” in the context menu (ri
ght mouse button) all files in the function
plan can be selected.
Now, the selected files can be diagnosed if the information in the function chart matches with the
functions in the actively connected SCU system.
Information:
The integrated trouble shooting function requires an intensive data transfer between
the SCU system and
SafePLC
2
.
This can cause a temporary delay in the display of data. Thus,
recent status changes at module outputsmay not be detected.
ATTENTION:
If the SCU module is set into alarm mode, the processrepresentation is no longer updated. The
change of input levels is no longer valid, and is no longer displayed in the diagnosis.