Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 150 of 252
Status: 19.03.2021
Two-hand control
Switch type
Description
Comment
11 (2 toggles)
2 closing co 2 opening contacts
Two-hand switch with higher requirements;
typ III C
12 (2 N.O.)
2 closing contacts
Two-hand switch (monitored)); type III A
Information
: These input elements cause a fixed impulse assignment which the user cannot
influence.
Limit switch
Switch type
Description
Comment
1 (1 N.C.)
1 opening contact
Activation switch (standard)rd
2 (1 N.O)
1 closing contacts
3 (2 N.C.)
2 opening contacts
Activation switch with higher requirements
4 (2 N.C. (time-controlled)
2 opening contacts (time-monitored)
Activation switch (monitored)
Master switch
Switch type is not supported with this device type
Light barrier
Switch type
Description
Comment
3 (2 N.C.)
2 opening contacts
Light barrier with higher requirements
4 (2 N.C. (time-monitored)
2 opening contacts (time-monitored)
Light barrier (monitored)
5 (1 N.O. 1 N.C.)
1 closing c 1 opening contact
Lichtschranke with higher requirements
6 (1 N.O. 1 N.C. (time
monitored)
1 closing c 1 opening contact
(time-monitored)
Light barrier (monitored)