Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 105 of 252
Status: 19.03.2021
Collection / Stop:
starts or stops the recording.
Pause:
Press the “Pause“
button to stop the displayed values in the main diagram. The data are
still available in the cache.
Reset:
reset of diagram values and process data.
Tip:
With a double click in the main diagram window, the cursor is inserted at this position. Thus,
the cursor is added in the value table for optional measurements.
Hold on change:
If the “
Hold on change
“
button isactive, the recording stops 2 seconds after a
slope change of the respective output (see above). This function allows longi-time recording and
error analysis in the absence of the operator.
Save: If the range has been stopped, the current recording can be saved in afile. In the file, the
range data are written as ASCII values. The índividual values have XML tags, so that the recording
can be used for documentation purposes or for the analysis connected to encoder configuration.
The data can also be shown with the Microsoft Explorer or with another XML viewer.
Load: With this control surface, a measurement saved under the range function of an XML file can
be loaded in the range. In this case, the range window changes to the view mode. Due to possible
differerences in encoder configuration of the displayed measurement for the current programme,
and the resulting deviances in the scaling of the position values and of the speed values, the
“Start” button and the plan
selection list are deenabled after the data have been loaded for display.
The measurements remain deenabled, until the range function is restarted.
Import: Import of a measurement from .ScpXml files.
Export: Export of the measurement of a selected output to an .ScpXml filei.
Figure 85 Selecting an output for export