Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 106 of 252
Status: 19.03.2021
4.6.12.1. Procedure of a measuring in the range
After the
range window has been opened, it still stands on “Stop“
, i.e., no cyclical process data
from the SCU system are read. To carry out a measurement that is faultless to the greatest extent,
you should proceed as described below.
NOTICE:
All Internet based and all LAN based programs running in the background should be closed before
the measuring.
4.6.12.2. Preparing measurement
Select the desired measuring plan. During a speed-oriented measurement, the running
control-time of the SCU module is shown on the X-axis. The running control-time is a continuously
rising meter for the system control signs of the SCU module. The measurement data are constantly
updated and are stored in the cache. The recoring memory is aprox. 15 minutes.
Measurement automatically stops when the cache is full. The preceding measurement is
automatically saved as
“ScopeTempData.ScpXml“.
During position-oriented measurement, the configured measuring range of the set axis is shown on
the X-axis.
NOTICE:
When the plan is changed, recorded data from the preceding measurements get lost. When the
window size is changed, the displayed data must be newly scaled. This requires position-oriented
measurement and the reset of the data buffer (SSX).
4.6.12.3. Starting measurement
The button “Erfassung“
[Capture] to start measurement is only available with an active connection
to the SCU system. After this button has been clicked on, the data are transferred cyclically into the
cache, and are shown in the diagram from left to right. An active recording can be stopped with the
“
Stopp
” [Stop] button.
4.6.12.4. Stopping measurement and indicating data
After measurement is finished, the data can be analysed by appropriately moving the shifting bar.