B. Remote Control Protocol
activatePreset
•
De
fi
nition
-
Recall a Preset on the Event Master processor. User can recall Preset with id, Preset serial number, or Preset name.
-
Send any one of the parameters to recall Preset.
•
Request params:
-
params:
{"id":
x, "type":
x}
-
params:
{"presetSno":
x.y, "type":
x}
-
params:
{"presetName":
"PresetName"}
o
“type”—0 to recall in preview (default), 1 to recall in program.
This is not a mandatory parameter but should be given when the user wants to recall a Preset in program.
•
Response:
-
response: null
-
success: (0=success, anything else is an error)
•
Example:
-
{"params":
{"id":
0, "type":
0}, "method":"activatePreset", "id":"1234", "json-
rpc":"2.0"} //Recall in preview with id 0
.
-
{"params":
{"presetName":
"abc" }, "method":"activatePreset", "id":"1234", "json-
rpc":"2.0"} //Recall in preview with preset name “abc”.
-
{"params":
{"presetSno":
1.00, "type":
1}, "method":"activatePreset", "id":"1234",
"jsonrpc":"2.0"} //Recall in program with presetSno 1.
recallNextPreset
•
De
fi
nition
-
Recall the next Preset on the Event Master processor.
No parameter is required.
-
Make sure that the user has at least recalled one Preset. Web app recalls the next Preset from the last Preset recalled.
•
Request:
-
params:
{}
•
Response:
-
response: null
-
success: (0=success, anything else is an error)
-
An error is shown if there was no last recalled Preset or if there is no next Preset in the list.
•
Example:
-
{"params":
{}, "method":" recallNextPreset", "id":"1234", "jsonrpc":"2.0"}
deletePreset
•
De
fi
nition
-
Delete a Preset on the Event Master processor.
User can delete Preset with id, Preset serial number, or Preset name.
-
Send any one of the parameters to delete Preset.
•
Request:
-
params:
{"id":
x}
-
params:
{"presetSno":
x.y}
-
params:
{"presetName":
"PresetName"}
•
Response:
-
response: null
-
success: (0=success, anything else is an error)
•
Example:
-
{"params":
{"id":
1}, "method":"deletePreset", "id":"1234", "jsonrpc":"2.0"}
-
{"params":
{"presetSno":
1.00}, "method":"deletePreset", "id":"1234", "jsonrpc":"2.0"}
-
{"params":
{"presetName":
"Preset 5.00"}, "method":"deletePreset", "id":"1234", "json-
rpc":"2.0"}
R5905948 EVENT MASTER DEVICES 17/07/2017
515
Summary of Contents for S3 series
Page 1: ...Event Master Devices User s Guide R5905948 05 17 07 2017 ...
Page 9: ...Table of contents Index 531 R5905948 EVENT MASTER DEVICES 17 07 2017 5 ...
Page 10: ...Table of contents 6 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 20: ...2 Safety 16 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 66: ...4 Hardware orientation 62 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 90: ...5 Front Panel Menu orientation 86 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 264: ...8 Updating firmware 260 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 268: ...9 General operation example Image 9 3 264 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 285: ...9 General operation example Image 9 25 R5905948 EVENT MASTER DEVICES 17 07 2017 281 ...
Page 288: ...9 General operation example 284 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 316: ...10 Controller orientation 312 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 326: ...11 Controller Configuration 322 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 352: ...12 Controller Operation 348 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 418: ...13 E2 Maintenance 414 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 488: ...16 EC 200 Maintenance 484 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 494: ...17 Environmental information 490 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 512: ...A Specifications 508 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 527: ...C Troubleshooting C TROUBLESHOOTING R5905948 EVENT MASTER DEVICES 17 07 2017 523 ...
Page 528: ...C Troubleshooting 524 R5905948 EVENT MASTER DEVICES 17 07 2017 ...