12. Controller Operation
The Rotary Encoders mapping will continue as suggested above but out of scope for R1.
Arrow Buttons
Image 12-8
The standard function is moving a layer just as in EMTS now.
When the Barco Eye Button is pressed and held the arrow buttons will allow for Z-Order alignment, selected layers will move one
Z-order up or down according to the arrow indication- Left arrow is top most Z-order Right arrow is bottom most Z-order.
Source
Image 12-9
Source refer to an source of image or video such as a Source
fi
le, Still store and Destination. See the earlier Chapters for the
de
fi
nition of Source.
When Source is pressed it lights its blue LED and opens the syntax entry for numbers and modi
fi
ers as per above and in detail below:
•
SOURCE # ENTER
will add Source
fi
le # to the selected layer or add a layer, just as dragging it in the GUI.
•
SOURCE 1 THRU 4 ENTER
will add Source
fi
le 1 to the Z-order
fi
rst selected layer and continue to add source
fi
les 2 – 4 to
Z-order layers 2 – 4 or add as many layers needed until no layers are available.
•
SOURCE 1 + 5 + 88 ENTER
will add Source
fi
le 1 to the Z-order
fi
rst selected layer and continue to add source
fi
les 5 and
88 to Z-order layers 2 – 3 or add as many layers needed until no layers are available.
Note: SOURCE syntax support the . (dot) as indicating a source
fi
le like 88.5
For live input sources, Source is the actual source
fi
le, not the input in number.
The contextual Buttons to the right of the numpad also light up and is populated with functionality that can be used in the syntax.
These are:
Contextual
Button
Display
Description
CD1
RESET Size
Once pressed Resets the Sizing Adjustments of the source in the selected Layer, just as
clicking the Blue Reset icon button in the GUI.
If multiple layer are selected, no source
fi
les sizing is Reset.
CD2
Create Source (
fi
le)
Creates new source
fi
le just like the plus button in the GUI
CD3
SAVE Source
Saves the source
fi
le
CD4
Sprocket Source
Adjustment
Opens the Adjust of the selected source on the Sprocket page.
CD5
Brush Color correction Opens the Adjust of the Color correction of the selected source on the Brush page
CD6
Empty
CD7
Snow
fl
ake (Freeze
input)
Will freeze the INPUT of the selected source
fi
le. If the selected source IS frozen it will
be un-frozen.
CD8
Bind
Binds Source
fi
le to User key per syntax.
SOURCE
# (is source
fi
le)
BIND
# (is user key number)
ENTER
CD9
Empty
CD10
Empty
340
R5905948 EVENT MASTER DEVICES 17/07/2017
Summary of Contents for S3 series
Page 1: ...Event Master Devices User s Guide R5905948 05 17 07 2017 ...
Page 9: ...Table of contents Index 531 R5905948 EVENT MASTER DEVICES 17 07 2017 5 ...
Page 10: ...Table of contents 6 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 20: ...2 Safety 16 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 66: ...4 Hardware orientation 62 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 90: ...5 Front Panel Menu orientation 86 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 264: ...8 Updating firmware 260 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 268: ...9 General operation example Image 9 3 264 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 285: ...9 General operation example Image 9 25 R5905948 EVENT MASTER DEVICES 17 07 2017 281 ...
Page 288: ...9 General operation example 284 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 316: ...10 Controller orientation 312 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 326: ...11 Controller Configuration 322 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 352: ...12 Controller Operation 348 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 418: ...13 E2 Maintenance 414 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 488: ...16 EC 200 Maintenance 484 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 494: ...17 Environmental information 490 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 512: ...A Specifications 508 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Page 527: ...C Troubleshooting C TROUBLESHOOTING R5905948 EVENT MASTER DEVICES 17 07 2017 523 ...
Page 528: ...C Troubleshooting 524 R5905948 EVENT MASTER DEVICES 17 07 2017 ...