Automation PC 620 User's Manual V 1.90
2.9.1 Serial interfaces COM1
I/O address and IRQ
The setting for the I/O address and the IRQ can be changed in the BIOS setup (under
"Advanced" - submenu "I/O Device Configuration" setting "Serial port A"). Please note any
potential conflicts with other resources when changing this setting.
Serial interfaces COM1
Type
RS232, modem-capable, not
electrically isolated
9-pin DSUB male
UART
16550 compatible, 16 byte
FIFO
Transfer rate
Max. 115 kBaud
Bus length
Max. 15 meters
Pin
Assignment
1
DCD
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
Table 22: Pin assignments - COM1
Resource
Default setting
Additional setting options
I/O address
3F8
2F8, 3E8, 2E8
IRQ
IRQ4
IRQ3
Table 23: COM1 - I/O address and IRQ