150
Technical data • Individual components
Automation PC 620 User's Manual V 1.90
Pin assignments
I/O address and IRQ
The setting for the I/O address and the IRQ can be changed in the BIOS setup (under
"Advanced" - submenu "Baseboard/Panel Features" - submenu "Legacy Devices", setting "COM
E"). Please note any potential conflicts with other resources when changing this setting.
Bus length and cable type RS232
The maximum transfer rate of 115 kBit/s depends on the cable type being used.
Add-on RS232/422/485
RS232
RS422/485
9-pin DSUB plug
Type
RS232; not modem capable;
electrically isolated
UART
16550 compatible, 16 byte FIFO
Transfer rate
Max. 115 kBit/s
Bus length
Max. 15 meters
Max. 1200 meters
Pin
Assignment
RS232
Pin assignments -
RS422
1
n.c.
TXD
2
RXD
n.c.
3
TXD
n.c.
4
n.c.
TXD
5
GND
GND
6
n.c.
RXD
7
RTS
n.c.
8
CTS
n.c.
9
n.c.
RXD
Table 77: Pin assignments - RS232/RS422
Resource
Default setting
Additional setting options
I/O address
2E8
238, 2F8, 338, 3E8, 3F8
IRQ
IRQ10
IRQ 3, 4, 5, 7, 11, 12
Table 78: Add-on RS232/422/485 - I/O address and IRQ
Distance [m]
Transfer rate [kBit/s]
≤
15
Type 64
≤
10
Type 115
≤
5
Type 115
Table 79: RS232 bus length and transfer rate
Summary of Contents for Automation PC 620
Page 2: ...2 Automation PC 620 User s Manual V 1 90...
Page 4: ...4 Automation PC 620 User s Manual V 1 90...
Page 6: ...6 Automation PC 620 User s Manual V 1 90...
Page 376: ...376 Maintenance servicing International certifications Automation PC 620 User s Manual V 1 90...
Page 487: ...Appendix A Glossary Appendix A 487 Automation PC 620 User s Manual V 1 90...
Page 488: ...488 Appendix A Glossary Automation PC 620 User s Manual V 1 90...
Page 512: ...Index 512 Automation PC 620 User s Manual V 1 90...