Automation PC 620 User's Manual V 1.90
BIOS setting
Description
Setting options
Effect
COM C
Settings for the internal serial interfaces in
the system. This setting activates the
touch screen in panel PC 700 systems,
and, using SDL transfer technology, also
in Automation Panel 900 display units.
Disabled
Deactivates the interface.
Enabled
Activates the interface.
Base I/O address
Selection of the base I/O address for the
COM C port.
A yellow star indicates a conflict with
another device.
238, 2E8, 2F8, 328, 338,
3E8, 3F8
Selected base I/O address is assigned.
Interrupt
Selection of the interrupt for the COM C
port.
A yellow star indicates a conflict with
another device.
IRQ 3, IRQ 4, IRQ 5, IRQ
7, IRQ 10, IRQ 11, IRQ
12
Selected interrupt is assigned.
COM D
Configuration of the COM D port for the
serial interface of an automation panel link
slot. The interface is used to operate the
touch screen on connected Automation
Panel 900 units.
Disabled
Deactivates the interface.
Enabled
Activates the interface.
Base I/O address
Configuration of the base I/O address for
the serial COM D port.
A yellow star indicates a conflict with
another device.
238, 2E8, 2F8, 328, 338,
3E8, 3F8
Selected base I/O address is assigned.
Interrupt
Selection of the interrupt for the COM D
port.
A yellow star indicates a conflict with
another device.
IRQ 3, IRQ 4, IRQ 5, IRQ
7, IRQ 10, IRQ 11, IRQ
12
Selected interrupt is assigned.
COM E
Configuration of the optional COM E port
of a B&R add-on interface option (IF
option).
Disabled
Deactivates the interface.
Enabled
Activates the interface.
Base I/O address
Configuration of the base I/O address for
the serial COM E port.
A yellow star indicates a conflict with
another device.
238, 2E8, 2F8, 328, 338,
3E8, 3F8
Selected base I/O address is assigned.
Interrupt
Selection of the interrupt for the COM E
port.
A yellow star indicates a conflict with
another device.
IRQ 3, IRQ 4, IRQ 5, IRQ
7, IRQ 10, IRQ 11, IRQ
12
Selected interrupt is assigned.
LPT
This setting is specific to B&R and should
not be changed.
Disabled
Deactivates the interface.
Enabled
Activates the interface.
Base I/O address
Configuration of the base I/O address for
the optional LPT.
A yellow star indicates a conflict with
another device.
278, 378, 3BC
Selected base I/O address is assigned.
CAN
Configuration of the CAN port of a B&R
add-on interface card.
Disabled
Deactivates the interface.
Enabled
Activates the interface.
Base I/O address
384/385h
None
-
Interrupt
Selection of the interrupt for the CAN port.
IRQ 10
Selected interrupt is assigned.
NMI
NMI interrupt is assigned.
Table 206: 855GME - Legacy devices - setting options
Summary of Contents for Automation PC 620
Page 2: ...2 Automation PC 620 User s Manual V 1 90...
Page 4: ...4 Automation PC 620 User s Manual V 1 90...
Page 6: ...6 Automation PC 620 User s Manual V 1 90...
Page 376: ...376 Maintenance servicing International certifications Automation PC 620 User s Manual V 1 90...
Page 487: ...Appendix A Glossary Appendix A 487 Automation PC 620 User s Manual V 1 90...
Page 488: ...488 Appendix A Glossary Automation PC 620 User s Manual V 1 90...
Page 512: ...Index 512 Automation PC 620 User s Manual V 1 90...