Similar to X-Y Grid, but there isn't a Y-axis. Set your drawing's
horizontal labels, spacing, and origin on the X Zones setup dialog
box.
X Zones
TIP
Use a negative zone spacing value if you want the zone ref-
erence origin to be at the right side of the drawing.
Each ladder column has a column of assigned reference numbers.
Reference Numbers
Specifies how to display ladder line reference numbers - number
only, numbers in a hexagon, the sheet and number values, and
so on.
Setup
Scale
Sets the scale factor used when inserting new com-
ponents or wire numbers on the drawing. To insert
Feature Scale Multiplier
everything 25% bigger than normal, change the edit
box value from 1.00 to 1.25.This change does not
affect components and wire numbers that are already
present on the drawing.
Select inch if your drawing is to use library symbols
from the JIC1/JIC125 libraries or mm full size for the
inch/inch scaled to mm/mm full size
metric scaled symbol libraries. This adjusts the wire
connection trap distance that determines whether
closely spaced wire ends connector not.
Tag/Wire Number Order
Sets the default wire numbering sort order for the active drawing.
You can set sorting on a per-drawing basis and override the project-
Sort Order
wide default setting defined in Properties
➤
Wire Numbers dialog
box. For example, you can set the wire numbers togo in a reverse
order from the I/O point on a PLC I/O drawing, but have the wire
numbers going from left to right for non-PLC I/O drawings.
Overview of project and drawing properties | 125
Summary of Contents for 22505-051400-9000 - AutoCAD Electrical 2008
Page 1: ...AutoCAD Electrical 2008 User s Guide February 20 2007 ...
Page 4: ...1 2 3 4 5 6 7 8 9 10 ...
Page 106: ...94 ...
Page 228: ...216 ...
Page 242: ...HP W TERM_ VDC SPECIAL SPACINGFACTOR 0 5 HP WA D TERM_ 02 230 Chapter 5 PLC ...
Page 294: ...282 ...
Page 564: ...552 ...
Page 698: ...686 ...
Page 740: ...728 ...
Page 814: ...802 ...
Page 1032: ...1020 ...
Page 1134: ...1122 ...
Page 1168: ...1156 ...
Page 1177: ...Insert P ID Component Overview of pneumatic tools 1165 ...
Page 1198: ...1186 ...
Page 1269: ...AutoCAD Electrical Command In this chapter AutoCAD Electrical Commands 20 1257 ...
Page 1304: ...Z zip utility 82 1292 Index ...