Chapter 3: Configuration and commissioning
1X-E4 Series Installation Manual
27
User level passwords and indications
The default user level passwords and the corresponding LED and seven-
segment display indications are shown in the table below. The seven-segment
display is only visible when the control panel cover is removed. See Figure 1 on
page 4.
Table 15: User level passwords and indications
User level
Password
LED
Default display Custom display
Public
None
None
None
None
Operator
2222
The Reset LED is
steady
None
None
Basic installer 3333
The Reset LED is
flashing
Advanced
installer
4444
The Reset LED is
flashing
Note:
If you have used advanced configuration options to set a custom input
configuration, zone delay, zone configuration, or zone type, then the seven-
segment display defaults to the custom display operating mode. See “Panel
mode” on page 36 for details.