![Amtech Axpert-Eazy AMT-011-4 Instruction Manual Download Page 93](http://html1.mh-extra.com/html/amtech/axpert-eazy-amt-011-4/axpert-eazy-amt-011-4_instruction-manual_2937000093.webp)
Axpert-Eazy
AC Variable Frequency Drive
6-47
6
A103
10V
F
V
A103
20mA
F
I
4mA
FSV 10-0V
FSI 20-4mA
A102
A102
6. FSV 10-0V
This is an inverse to option-2. When this option is selected, the set frequency
M105
corresponds to
analog input FSV. The output frequency will be minimum at 10 V and maximum at 0 V.
7. FSI 20-4mA
This is an inverse to option-3. When this option is selected, the set frequency
M105
corresponds to
analog input FSI. The output frequency will be minimum at 20 mA and maximum at 4 mA. The
maximum limit is decided by
A103
.
8. FSV 5-0V
This is an inverse to option-4. When this option is selected, the set frequency
M105
corresponds to
analog input FSV. The output frequency will be minimum at 5 V and maximum at 0 V.
9. FSI 20-0mA
This is an inverse to option-5. When this option is selected, the set frequency
M105
corresponds to
analog input FSI. The output frequency will be minimum at 20 mA and maximum at 0 mA.
10. Static potentiometer
When this option is selected, the set frequency
M105
will be decided by programmable sequence
inputs. Assign two programmable sequence inputs to
Freq Increase
and
Freq Decrease
respectively. When
Freq Increase
is applied, the set frequency will increase and when
Freq
Decrease
is applied, the frequency will decrease. If both the signals are applied simultaneously, it will
have no effect. The rate of frequency increase / decrease is 0.1 Hz at every 100msec.
11. Serial
In this option, the set frequency
M105
can be assigned from serial link.
12. PID Output
In this option, the PID output will be the set point. When selecting this input, enable the PID Control in
C601. The monitor option M105 will display the corresponding set frequency value, even if the AC
DRIVE is stop
.
For more information on PID control, refer Mode-C, Group-6 parameters.
13. VIN 0-10V
When this option is selected, the set frequency
M105
corresponds to analog input VIN. The output
frequency will be minimum at 0 V and maximum at 10 V.
Summary of Contents for Axpert-Eazy AMT-011-4
Page 2: ...Amtech ii...
Page 19: ...Axpert Eazy AC Variable Frequency Drive 2 11 2 400V Series AMT 200 4 AMT 250 4...
Page 22: ...Amtech 2 14 2 This Page is intentionally left blank...
Page 37: ...Axpert Eazy AC Variable Frequency Drive 4 9 4...
Page 38: ...Amtech 4 10 4 This page is intentionally left blank...
Page 46: ...Amtech 5 8 5 This page is intentionally left blank...
Page 216: ...Amtech 13 6 13 This page is intentionally left blank...
Page 221: ...Axpert Eazy AC Variable Frequency Drive A 5 13 A Outline Dimensions...
Page 239: ...Notes...
Page 240: ...Notes...
Page 241: ......
Page 242: ...AMTECH...