MODE-D: Auxiliary Drive Parameters
No.
Parameter
Unit
Def
Min
Max
Res
Description
WP
GROUP-1: MOTOR PARAMETERS
D101 Motor Voltage
Vac
415
380
480
1
This is the Motor rated Voltage. Set the voltage
mentioned on the motor nameplate. The setting
value depends on the 400V, 500V, 600V or
200V Series model.
575
500
575
690
600
690
230
200
240
D102 Motor Current
Amp M304
0.3*
M304
M304
0.1
Insert the rated motor current from the
nameplate.
D103 Motor Frequency
Hz
50.0
10.0
600.0
0.1
Set the rated base frequency from the
nameplate.
D104 Motor Speed
rpm
1500
1
36000
1
Set the base speed from the motor nameplate.
D105 Motor Output
Rating
kW
M305
0.1
1500.0
0.1
The motor’s rated output at the base speed is
set from the nameplate.
GROUP-2: FREQUENCY SETTING
D201 Local Set
Frequency
Hz
10.00
0.00
600.00
0.01 This is the frequency set from the operation
panel for auxiliary motor.
D202 Min Frequency
Hz
0.10
0.00
600.00
0.01 These two Parameters are used to configure
Minimum and Maximum Frequency of the AC
DRIVE for auxiliary motor.
D203 Max Frequency
Hz
50.00
0.10
600.00
0.01
D204 Frequency
Reference Input
1
1
18
1
This is used to select the speed reference for
auxiliary drive.
=1: Local
=3: FSI 4-20mA
=5: FSI 0-20mA
=7: FSI 20-4mA
=9: FSI 20-0mA
=11: Serial
=13: VIN 0-10V
=15: PLC A-O/P 1
=17: PLC A-O/P 3
=2: FSV 0-10V
=4: FSV 0-5V
=6: FSV 10-0V
=8: FSV 5-0V
=10: Static pot
=12: PID Output
=14: IIN 4-20mA
=16: PLC A-O/P 2
=18: PLC A-O/P 4
D205 Line Speed Setting rpm
1500
0
3000
1
The set value will be displayed as motor speed
in
M102
at 50Hz when auxiliary drive is
selected.
D206 Acceleration Time-
1
Sec
10.0
0.1
6000.0
0.1
Time needed for the speed to change from zero
to maximum.
D207 Deceleration Time-
1
Sec
20.0
0.1
6000.0
0.1
Time needed for the speed to change from
maximum to zero.
GROUP-3: TORQUE BOOST
D301 Manual Torque
Boost
Setting
%
0
0.0
20.0
0.1
When setting manually, set the boost voltage at
0Hz as a percentage in respect to the rated
output voltage. When programmed to zero, it
will be disabled. This is automatically adjusted
by the automatic tuning.
D302 Slip Compensation
Hz
0.0
0.0
5.0
0.1
Set the motor’s rated slip. When setting
manually, set the slip frequency for the motor
rated load in respect to the base frequency. The
output frequency changes according to the
motor rated torque.
D303 DC Brake Start
Frequency
Hz
1.50
0.00
50.00
0.01 It is a frequency at which DC braking is initiated
during stop.
D304 DC Brake Current
%
50
15
150
1
Configure amount of current available for the
DC braking when DC braking is used during
stop.
Summary of Contents for Axpert-Eazy AMT-011-4
Page 2: ...Amtech ii...
Page 19: ...Axpert Eazy AC Variable Frequency Drive 2 11 2 400V Series AMT 200 4 AMT 250 4...
Page 22: ...Amtech 2 14 2 This Page is intentionally left blank...
Page 37: ...Axpert Eazy AC Variable Frequency Drive 4 9 4...
Page 38: ...Amtech 4 10 4 This page is intentionally left blank...
Page 46: ...Amtech 5 8 5 This page is intentionally left blank...
Page 216: ...Amtech 13 6 13 This page is intentionally left blank...
Page 221: ...Axpert Eazy AC Variable Frequency Drive A 5 13 A Outline Dimensions...
Page 239: ...Notes...
Page 240: ...Notes...
Page 241: ......
Page 242: ...AMTECH...