During 32-bit load and store commands user should use only 0 to 84 16-bit memory locations.
Example 6.
This application can be used to monitor feedback on FSV and convert it to other quantity by
the use of PLC and display on Display Panel to monitor up to certain limit and give trip
(External Fault).
Program Code:
Input from Display Panel into P101 to PA01.
Parameter No.
PLC Command
Description
P101
016094108000
Multiplication between Register 94 and 108 and result will be stored
in 32-bit memory location.
P102
001001000100
Copy 16-bit Immediate value (100) into Register no.1
P103
018001000000
Division between 32-bit memory location and register 1 and result
will be stored in 32-bit memory location
P104
003010000000
The value of 32-bit memory location is stored in Register 10 as high
and register 11 as low 16-bit value.
P105
028012010011
Word OR logic between Register 10 and 11 and result will be store
in Register 12.
P106
061001012000
Display Register 12 in PLC Display Number 1.
P107
035001012102
If Register 12 is greater than Register 102 then Flag number 1 will
be set
P108
048012001000
Status of flag 1 will be written to
12:EXT_FLT
option of PSI's
selectable options.
P109
000000000000
End of Program.
User has to set following parameter.
1. Enable PLC function from C312.
2. Register 94 contains FSV input, which is read only memory location.
3. Register 108 contains value of Panel Para8
(C708)
which is used for multiplication factor,
and that should be change as per input quantity range.
Note:
There is only one 32-bit memory location is given.
During 32-bit load and store commands user should use only 0 to 84 16-bit memory locations.
Summary of Contents for Axpert-Eazy AMT-011-4
Page 2: ...Amtech ii...
Page 19: ...Axpert Eazy AC Variable Frequency Drive 2 11 2 400V Series AMT 200 4 AMT 250 4...
Page 22: ...Amtech 2 14 2 This Page is intentionally left blank...
Page 37: ...Axpert Eazy AC Variable Frequency Drive 4 9 4...
Page 38: ...Amtech 4 10 4 This page is intentionally left blank...
Page 46: ...Amtech 5 8 5 This page is intentionally left blank...
Page 216: ...Amtech 13 6 13 This page is intentionally left blank...
Page 221: ...Axpert Eazy AC Variable Frequency Drive A 5 13 A Outline Dimensions...
Page 239: ...Notes...
Page 240: ...Notes...
Page 241: ......
Page 242: ...AMTECH...