![Amtech Axpert-Eazy AMT-011-4 Instruction Manual Download Page 57](http://html1.mh-extra.com/html/amtech/axpert-eazy-amt-011-4/axpert-eazy-amt-011-4_instruction-manual_2937000057.webp)
Axpert-Eazy
AC Variable Frequency Drive
6-11
6
No.
Parameter
Unit
Def
Min
Max
Res.
Description
WP
B117 Encoder Polarity
0
0
1
1
This is used to select Encoder polarity.
=0:Forward
=1:Reverse
B118 No Load Output
Current
Amp
0.3*
M304
1.0
M304
0.1
Set the motor no load current.
B119 Motor Overload
Selection
3
1
5
1
=1: 120% for 60 Sec
=2: 150% for 60 Sec
=3: 150% for 120 Sec
=4: 150% for 180 Sec
=5: 150% for 240 Sec
GROUP-2: MOTOR CONSTANTS
B201 Automatic Tuning
Selection
1
1
5
1
The Automatic tuning mode is selected.
=1: Disable Auto-tuning
=2: Stationary (Belt ON) (For V/F control)
=3: Rotational (Belt OFF) (For Vector
control)
=4: Extended Rotational (Belt OFF) (For
Vector control)
=5: Reserved
B202 R1: Primary-Stator
Resistance
Mantissa)
m
Ω
Inv
rating
0.100
9.999
0.001 The motor circuit constant is set.
This combination means below.
B202 = 1.000, B203 = 0
R1 = 1.000 (B202) x (10)
0 (B203)
[m
Ω
]
= 1.000 [m
Ω
]
B203 R1: Primary-Stator
Resistance
(Exponent)
Inv
rating
-3
4
1
B204 R2’: Secondary-
Rotor Resistance
(Mantissa)
m
Ω
1.000 0.100
9.999
0.001 This is mantissa section of the entered value for
Secondary (Rotor) Resistance of motor.
B205 R2’: Secondary-
Rotor Resistance
(Exponent)
0
-3
4
1
This is exponent section of the entered value for
Secondary (Rotor) Resistance of motor.
B206 L: Leakage
Inductance
(Mantissa)
mH
1.000 0.100
9.999
0.001 This is mantissa section of the entered value for
Leakage Inductance of motor.
B207 L: Leakage
Inductance
(Exponent)
0
-3
4
1
This is exponent section of the entered value for
Leakage Inductance of motor.
B208 M’: Excitation
Inductance
(Mantissa)
mH
1.000 0.100
9.999
0.001 This is mantissa section of the entered value for
Excitation Inductance.
B209 M’: Excitation
Inductance
(Exponent)
0
-3
4
1
This is exponent section of the entered value for
Excitation Inductance.
B210 Rm: Iron Loss
Resistance
(Mantissa)
m
Ω
1.000 0.100
9.999
0.001 This is mantissa section of the entered value for
Iron Loss Resistance.
B211 Rm: Iron Loss
Resistance
(Exponent)
0
-3
5
1
This is exponent section of the entered value for
Iron Loss Resistance.
GROUP-3: PROTECTION PARAMETERS
B301 Stall Current Limit
%
125.0
0.0
200.0
0.1
Set the current value as a percentage of motor
rated current for normal running condition. The
default value is 125% for normal duty and 155%
for heavy duty mode.
Summary of Contents for Axpert-Eazy AMT-011-4
Page 2: ...Amtech ii...
Page 19: ...Axpert Eazy AC Variable Frequency Drive 2 11 2 400V Series AMT 200 4 AMT 250 4...
Page 22: ...Amtech 2 14 2 This Page is intentionally left blank...
Page 37: ...Axpert Eazy AC Variable Frequency Drive 4 9 4...
Page 38: ...Amtech 4 10 4 This page is intentionally left blank...
Page 46: ...Amtech 5 8 5 This page is intentionally left blank...
Page 216: ...Amtech 13 6 13 This page is intentionally left blank...
Page 221: ...Axpert Eazy AC Variable Frequency Drive A 5 13 A Outline Dimensions...
Page 239: ...Notes...
Page 240: ...Notes...
Page 241: ......
Page 242: ...AMTECH...